| //   DEVICE-SPECIFIC LED SERVICES //
 | |
| ////////////////////////////////////
 | |
| 
 | |
| struct DEV_LED : Service::LightBulb {
 | |
| 
 | |
|   int ledPin;
 | |
|   SpanCharacteristic *power;
 | |
|   
 | |
|   DEV_LED(int ledPin) : Service::LightBulb(){
 | |
| 
 | |
|     power=new Characteristic::On();
 | |
|     this->ledPin=ledPin;
 | |
|     pinMode(ledPin,OUTPUT);    
 | |
|     WEBLOG("Configuring LED on Pin %d",ledPin);                         // NEW!  This creates a Web Log message announcing the configuration of the device
 | |
|     
 | |
|   } // end constructor
 | |
| 
 | |
|   boolean update(){            
 | |
| 
 | |
|     digitalWrite(ledPin,power->getNewVal());    
 | |
|     WEBLOG("LED on Pin %d: %s",ledPin,power->getNewVal()?"ON":"OFF");   // NEW!  This creates a Web Log message whenever an LED is turned ON or OFF
 | |
|     return(true);
 | |
|   
 | |
|   } // update
 | |
| };
 | |
|       
 | |
| //////////////////////////////////
 | |
| 
 | |
| // SOME MORE ABOUT WEB LOGGING
 | |
| // ---------------------------
 | |
| //
 | |
| // * The WEBLOG() macro operates by calling Serial.printf(), so the first argument always needs to be a text string containing printf-like format instructions.
 | |
| //   The rest of the arguments, if any, are the variables to print.  For example, you cannot simply write WEBLOG(ledPin).  This will cause errors at compile time,
 | |
| //   though you can write LOG1(ledPin) or LOG2(ledPin) to output log messages just to the Serial Monitor.
 | |
| //
 | |
| // * You do NOT need to include a "\n" at the end of your format string since all Web Log messages are formatted into an HTML table when presented, and HTML ignores "\n".
 | |
| //
 | |
| // * Every Web Log message is recorded with TWO timestamps.  The first timestamp is relative to when the device first booted, and is presented as DAYS:HH:MM:SS.  This timestamp
 | |
| //   is always present.  The second timestamp is an absolute clock time, in standard Unix form, such as "Mon Aug 10 13:52:48 2020".  This timestamp will only be present
 | |
| //   if the clock time of the device was set, else it will be shown as "Unknown".  Note that in the example above, the first Web Log message ("Configuring...") will
 | |
| //   have a clock timestamp of "Unknown" even though we enabled Web Logging with a Time Server.  This is because the Time Server cannot be configured until WiFi has
 | |
| //   been established, and the first Web Log message above is created during initial configuratin of the device, BEFORE a WiFi connection is made.  This is perfectly fine to do.
 | |
| //
 | |
| // * Every Web Log message also includes the IP Address of the Client that made the request, unless the Web Log message was generated independently of any Client request,
 | |
| //   such as in the first message above.  In these cases the IP Address will be displayed as 0.0.0.0.
 | |
| //
 | |
| // * Web Log messages are printed to the Serial Monitor whenever the HomeSpan Log Level is set to 1 or greater.  Hence there is no reason to duplicate the same message
 | |
| //   using WEBLOG() and LOG1() at the same time.
 |