@ -181,11 +181,11 @@ The following **optional** `homeSpan` methods enable additional features and pro
|
|||
* can by called from anywhere in a sketch
|
||||
|
||||
* `void enableWebLog(uint16_t maxEntries, const char *timeServerURL, const char *timeZone, const char *logURL)`
|
||||
* enables a rolling web log that displays the most recent *maxEntries* entries created by the user with the `WEBLOG()` macro. Parameters, and their default values if unspecified, are as follows:
|
||||
* *maxEntries* - maximum number of (most recent) entries to save. If unspecified, defaults to 0, in which case the web log will only display status without any log entries
|
||||
* enables a rolling Web Log that displays the most recent *maxEntries* entries created by the user with the `WEBLOG()` macro. Parameters, and their default values if unspecified, are as follows:
|
||||
* *maxEntries* - maximum number of (most recent) entries to save. If unspecified, defaults to 0, in which case the Web Log will only display status without any log entries
|
||||
* *timeServerURL* - the URL of a time server that HomeSpan will use to set its clock upon startup after a WiFi connection has been established. If unspecified, default to NULL, in which case HomeSpan skips setting the device clock
|
||||
* *timeZone* - specifies the time zone to use for setting the clock. Uses standard Unix timezone formatting as interpreted by Espressif IDF. Note the IDF uses a somewhat non-intuitive convention such that a timezone of "UTC+5:00" *subtracts* 5 hours from UTC time, and "UTC-5:00" *adds* 5 hours to UTC time. If *serverURL=NULL* this field is ignored; if *serverURL!=NULL* this field is required
|
||||
* *logURL* - the URL of the log page for this device. If unspecified, defaults to "status"
|
||||
* *logURL* - the URL of the Web Log page for this device. If unspecified, defaults to "status"
|
||||
* example: `homeSpan.enableWebLog(50,"pool.ntp.org","UTC-1:00","myLog");` creates a web log at the URL *http<nolink>://HomeSpan-\[DEVICE-ID\].local:\[TCP-PORT\]/myLog* that will display the 50 most-recent log messages produced with the WEBLOG() macro. Upon start-up (after a WiFi connection has been established) HomeSpan will attempt to set the device clock by calling the server "pool.ntp.org" and adjusting the time to be 1 hour ahead of UTC.
|
||||
* when attemping to connect to *timeServerURL*, HomeSpan waits 10 seconds for a response. If no response is received after the 10-second timeout period, HomeSpan assumes the server is unreachable and skips the clock-setting procedure. Use `setTimeServerTimeout()` to re-configure the 10-second timeout period to another value
|
||||
* see [Message Logging](Logging.md) for complete details
|
||||
|
|
@ -194,8 +194,8 @@ The following **optional** `homeSpan` methods enable additional features and pro
|
|||
* changes the default 10-second timeout period HomeSpan uses when `enableWebLog()` tries set the device clock from an internet time server to *tSec* seconds
|
||||
|
||||
* `void setWebLogCSS(const char *css)`
|
||||
* sets the CSS style page use by the web log to a user-define CSS specified by *css*
|
||||
* see [Message Logging](Logging.md) for complete details
|
||||
* sets the format of the HomeSpan Web Log to the custom style sheet specified by *css*
|
||||
* see [Message Logging](Logging.md) for details on how to construct *css*
|
||||
|
||||
* `void processSerialCommand(const char *CLIcommand)`
|
||||
* processes the *CLIcommand* just as if were typed into the Serial Monitor
|
||||
|
|
|
|||